Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1304: 342555, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38637039

RESUMO

BACKGROUND: Omics is used as an analytical tool to investigate wine authenticity issues. Aging authentication ensures that the wine has undergone the necessary maturation and developed its desired organoleptic characteristics. Considering that aged wines constitute valuable commodities, the development of advanced omics techniques that guarantee aging authenticity and prevent fraud is essential. RESULTS: Α solid phase microextraction Arrow method combined with comprehensive two-dimensional gas chromatography-mass spectrometry was developed to identify volatiles in red wines and investigate how aging affects their volatile fingerprint. The method was optimized by examining the critical parameters that affect the solid phase microextraction Arrow extraction (stirring rate, extraction time) process. Under optimized conditions, extraction took place within 45 min under stirring at 1000 rpm. In all, 24 monovarietal red wine samples belonging to the Xinomavro variety from Naoussa (Imathia regional unit of Macedonia, Greece) produced during four different vintage years (1998, 2005, 2008 and 2015) were analyzed. Overall, 237 volatile compounds were tentatively identified and were treated with chemometric tools. Four major groups, one for each vintage year were revealed using the Hierarchical Clustering Analysis. The first two Principal Components of Principal Component Analysis explained 86.1% of the total variance, showing appropriate grouping of the wine samples produced in the same crop year. A two-way orthogonal partial least square - discriminant analysis model was developed and successfully classified all the samples to the proper class according to the vintage age, establishing 17 volatile markers as the most important features responsible for the classification, with an explained total variance of 88.5%. The developed prediction model was validated and the analyzed samples were classified with 100% accuracy according to the vintage age, based on their volatile fingerprint. SIGNIFICANCE: The developed methodology in combination with chemometric techniques allows to trace back and confirm the vintage year, and is proposed as a novel authenticity tool which opens completely new and hitherto unexplored possibilities for wine authenticity testing and confirmation.


Assuntos
Compostos Orgânicos Voláteis , Vinho , Vinho/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microextração em Fase Sólida/métodos , Quimiometria , Análise por Conglomerados , Compostos Orgânicos Voláteis/análise
2.
J Chromatogr A ; 1708: 464366, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37716085

RESUMO

Fabric Phase Sorptive Extraction (FPSE) combined with high pressure liquid chromatography using to diode array detection (HPLC-DAD) was applied for the simultaneous determination of bisphenols (BPA, BPB, BPC, BPE, BPF, BPS) in juice pouches. The FPSE procedure was optimized with regards to the critical parameters that affect the performance of the method including the selection of the FPSE membrane type and size, adsorption time, extraction time, solvent volume desorption, magnetic stirring ratio, and salt addition. The FPSE membrane could be reused up to 14 times. The developed FPSE-HPLC-DAD method was validated in terms of linearity, sensitivity, accuracy andprecision. The limits of detection (LODs) were lower than 6.9 ng/mL, while the limits of quantification (LOQs) were lower than 21 ng/mL. The results obtained are satisfactory in terms of precision, accuracy and repeatability, with recoveries above 86% and CV values below 9.5%. The FPSE-HPLC-DAD method was successfully applied in the determination of six bisphenols in juice samples stored in pouches.


Assuntos
Alimentos , Cloreto de Sódio na Dieta , Cromatografia Líquida de Alta Pressão , Adsorção
3.
Anal Chim Acta ; 1268: 341400, 2023 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-37268341

RESUMO

The proof-of-concept of an integrated automatic foam microextraction lab-in-syringe (FME-LIS) platform coupled to high performance liquid chromatography is presented. Three different sol-gel coated foams were synthesized, characterized, and conveniently packed inside the glass barrel of the LIS syringe pump, as an alternative approach for sample preparation, preconcentration and separation. The proposed system efficiently combines the inherent benefits of lab-in-syringe technique, the good features of sol-gel sorbents, the versatile nature of foams/sponges, as well as the advantages of automatic systems. Bisphenol A (BPA) was used as model analyte, due to the increasing concern for the migration of this compound from household containers. The main parameters that affect the extraction performance of the system were optimized and the proposed method was validated. The limit of detection for BPA were 0.5 and 2.9 µg L-1, for a sample volume of 50 mL and 10 mL, respectively. The intra-day precision was <4.7% and the inter-day precision was <5.1% in all cases. The performance of the proposed methodology was evaluated for the migration studies of BPA using different food simulants, as well as for the analysis of drinking water. Good method applicability was observed based on the relative recovery studies (93-103%).

4.
Food Chem ; 424: 136423, 2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-37247598

RESUMO

In this work, different sol-gel sorbent-coated second-generation fabric phase sorptive extraction (FPSE) membranes were synthesized using titania-based sol-gel precursors. The proposed membranes were tested for their efficiency to extract eleven selected organophosphorus pesticides (OPPs) from apple juice samples. Among the examined materials, sol-gel C18 coated titania-based FPSE membranes showed the highest extraction efficiency. These membranes were used for the optimization and validation of an FPSE method prior to analysis by gas chromatography-mass spectrometry. The detection limits for OPPs ranged between 0.03 and 0.08 ng mL-1. Moreover, the relative standard deviation was < 8.2% and 8.4% for intra-day and inter-day studies, respectively. The relative recoveries were 91-110% (intra-day study) and 90-106% (inter-day study) for all the target analytes, demonstrating good overall method accuracy. Moreover, the novel membranes were reusable at least 5 times. The titania-based membranes were compared to the conventional silica-based membranes and their utilization resulted in higher extraction recoveries.


Assuntos
Malus , Praguicidas , Cromatografia Gasosa-Espectrometria de Massas/métodos , Praguicidas/análise , Compostos Organofosforados/análise
5.
Anal Bioanal Chem ; 415(13): 2547-2560, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36629895

RESUMO

In this work, a solid-phase microextraction (SPME) Arrow method combined with comprehensive two-dimensional gas chromatography-mass spectrometry (GC × GC-MS) was developed for the elucidation of the volatile composition of honey samples. The sample preparation protocol was optimized to ensure high extraction efficiency of the volatile organic compounds (VOCs) which are directly associated with the organoleptic properties of honey and its acceptance by the consumers. Following its optimization, SPME Arrow was compared to conventional SPME in terms of sensitivity, precision, and number of extracted VOCs. The utilization of SPME Arrow fibers enabled the determination of 203, 147, and 149 compounds in honeydew honey, flower honey, and pine honey, respectively, while a significantly lower number of compounds (124, 94, and 111 for honeydew honey, flower honey, and pine honey, respectively) was determined using conventional SPME. At the same time, the utilization of SPME Arrow resulted in enhanced sensitivity and precision. All things considered, SPME Arrow and GC × GC-MS can be considered as highly suitable for the elucidation of the volatile composition of complex food samples resulting in high sensitivity and separation efficiency.


Assuntos
Mel , Compostos Orgânicos Voláteis , Cromatografia Gasosa-Espectrometria de Massas/métodos , Mel/análise , Microextração em Fase Sólida/métodos , Compostos Orgânicos Voláteis/análise
6.
Methods Protoc ; 5(4)2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35893587

RESUMO

Nanomaterials are materials in which at least one of the three dimensions ranges from 1 to 100 nm, according to the International Organization for Standardization (ISO). Nanomaterials can be categorized according to various parameters, such as their source, their shape, and their origin. Their increasing use in industrial settings, everyday items, electronic devices, etc. poses an environmental and biological risk that needs to be assessed and appropriately addressed. The development of reliable analytical methods for both characterization and quantification of nanomaterials in various matrices is essential. This review summarized the recent trends in analytical methodologies for the characterization and determination of nanoparticles in biological matrices.

7.
Methods Protoc ; 5(3)2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35645346

RESUMO

Aquaculture, a mass supplier of seafood, relies on plastic materials that may contain the endocrine disruptors bisphenol-A (BPA) and tert-octylphenol (t-OCT). These pollutants present toxicity to Artemia, the live aquaculture feed, and are transferred through it to the larval stages of the cultured organisms. The purpose of this work is the development and validation of an analytical method to determine BPA and t-OCT in Artemia and their culture medium, using n-octylphenol as the internal standard. Extraction of the samples was performed with H2O/TFA (0.08%)-methanol (3:1), followed by SPE. Analysis was performed in a Nucleosil column with mobile phases A (95:5, v/v, 0.1% TFA in H2O:CH3CN) and B (5:95, v/v, 0.08% TFA in H2O:CH3CN). Calibration curves were constructed in the range of concentrations expected following a 24 h administration of BPA (10 µg/mL) or t-OCT (0.5 µg/mL), below their respective LC50. At the end of exposure to the pollutants, their total levels appeared reduced by about 32% for BPA and 35% for t-OCT, and this reduction could not be accounted for by photodegradation (9-19%). The developed method was validated in terms of linearity, accuracy, and precision, demonstrating the uptake of BPA and t-OCT in Artemia.

8.
J Chromatogr A ; 1672: 463026, 2022 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-35447527

RESUMO

Benzoyl urea insecticides are a class of pesticides used in agriculture for the inhibition of chitin synthesis in pests. These compounds are persistent in environmental samples, and thus their monitoring is necessary to avoid detrimental effects to human health and the environment. Magnet integrated fabric phase sorptive extraction (MI-FPSE) is a recently introduced sample preparation technique that combines sample stirring and analyte extraction into one stand-alone device. However, the applicability and the potential benefits of this technique in environmental analysis remain unexplored. In the present study, MI-FPSE was employed for the first time for the extraction and preconcentration of benzoyl urea insecticides (i.e., diflubenzuron, triflumuron, hexaflumuron, lufenuron and chlorfluazuron) from environmental water samples prior to their determination by high performance liquid chromatography-diode array detection (HPLC-DAD). The main factors affecting the performance of the proposed methodology were thoroughly investigated and optimized and the MI-FPSE-HPLC-DAD method was validated. The proposed method enabled the handling of relatively high sample quantity resulting in high preconcentration factors (501 and 731) and good sensitivity. Under optimum conditions, the limits of detection and the limits of quantification for the benzoyl urea insecticides were 0.06 ng mL-1 and 0.20 ng mL-1, respectively. Moreover, the relative standard deviations were less than 6.1% for intra-day study and less than 8.2% for inter-day study showing good method precision. After its validation, the herein developed method was successfully employed for the analysis of tap, mineral, river, and lake water samples. In addition, the ComplexGAPI index was used to present the green potential of developed method from the step of MI-FPSE device preparation to final determination. All things considered, MI-FPSE could potentially serve as an efficient tool for the monitoring of pollutants in environmental analysis.


Assuntos
Inseticidas , Poluentes Químicos da Água , Cromatografia Líquida de Alta Pressão , Humanos , Inseticidas/análise , Imãs , Ureia , Água , Poluentes Químicos da Água/análise
9.
Molecules ; 27(4)2022 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-35209222

RESUMO

Two novel microwave-assisted extraction (MAE) methods were developed for the isolation of phenols and tocopherols from pistachio nuts. The extracts were analyzed by reversed-phase high-pressure liquid chromatography coupled with a UV detector (RP-HPLC-UV). In total, eighteen pistachio samples, originating from Greece and Turkey, were analyzed and thirteen phenolic compounds, as well as α-tocopherol, (ß + γ)-tocopherol, and δ-tocopherol, were identified. The analytical methods were validated and presented good linearity (r2 > 0.990) and a high recovery rate over the range of 82.4 to 95.3% for phenols, and 93.1 to 96.4% for tocopherols. Repeatablility was calculated over the range 1.8-5.8%RSD for intra-day experiments, and reproducibility over the range 3.2-9.4%RSD for inter-day experiments, respectively. Principal component analysis (PCA) was employed to analyze the differences between the concentrations of the bioactive compounds with respect to geographical origin, while agglomerative hierarchical clustering (AHC) was used to cluster the samples based on their similarity and according to the geographical origin.


Assuntos
Fracionamento Químico , Quimiometria/métodos , Cromatografia Líquida de Alta Pressão , Micro-Ondas , Nozes/química , Compostos Fitoquímicos/análise , Pistacia/química , Fracionamento Químico/métodos , Análise por Conglomerados , Grécia , Fenóis/análise , Pistacia/classificação , Tocoferóis/análise , Tocoferóis/química , Turquia
10.
J Chromatogr A ; 1664: 462785, 2022 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-34992043

RESUMO

Α novel, green, and facile fabric phase sorptive extraction (FPSE) prior to high pressure liquid chromatography with diode array detection (HPLC-DAD) methodology was developed for the efficient extraction and quantitative determination of tocopherols (α-, sum of (ß+γ), and δ-) in edible oils. Among several highly hydrophobic FPSE membranes, sol-gel polycaprolactone-polydimethylsiloxane-polycaprolactone (sol-gel PCAP-PDMS-PCAP) coated polyester FPSE membrane was found as the most efficient in extracting tocopherol homologues from edible oil samples. To maximize the extraction efficiency of FPSE membrane, major parameters of FPSE including the membrane size, sample loading time, the choice of the appropriate elution solvent and the elution solvent volume, desorption time, and the influence of stirring were systematically optimized. The developed FPSE-HPLC-DAD methodology was validated and presented adequately low limits of detection (LODs) and limits of quantification (LOQs) over the ranges 0.05-0.10 µg/g, and 0.17-0.33 µg/g, respectively. The RSD% of the within-day and between-day assays were lower than 1.3, and 11.8, respectively, demonstrating good method precision. The trueness of the method was assessed by means of relative percentage of recovery and ranged between 90.8 and 95.1% for within-day assay, and between 88.7-92.8% for between-day assay. The developed methodology was applied in the analysis of edible oils.


Assuntos
Têxteis , Tocoferóis , Cromatografia Líquida de Alta Pressão , Interações Hidrofóbicas e Hidrofílicas , Óleos de Plantas
11.
Food Chem ; 373(Pt B): 131517, 2022 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-34772569

RESUMO

Triazine herbicides are a class of common pesticides which are widely used to control the weeds in many agricultural crops. Although many studies have described methodologies for the determination of triazine herbicides in aqueous samples, the attention given to agricultural crops and their products is far more limited. In this study, a novel sol-gel zwitterionic multi-mode fabric phase sorptive extraction (FPSE) platform was developed for the matrix clean-up, extraction and preconcentration of five triazine herbicides from fruit juice samples prior to their determination by high performance liquid chromatography-diode array detection (HPLC-DAD). The novel zwitterionic multi-mode sorbent was characterized and its performance for fruit juice analysis was evaluated. Compared to other sol-gel sorbents, the novel zwitterionic sorbent helped cleaning all the acidic interferences from fruit juices. The herein reported FPSE protocol was optimized and validated. Under optimum conditions, the FPSE method showed good accuracy, precision and sensitivity. The limits of detection and limits of quantification for all analytes were 0.15 ng mL-1 and 0.50 ng mL-1, respectively. The enhancement factors of this method ranged between 36.7 and 51.8. The relative standard deviation for intra-day precision was below 5.6% and for inter-day precision was below 8.8%. Finally, the proposed FPSE-HPLC-DAD method was successfully employed for the analysis of various fruit juice samples.


Assuntos
Herbicidas , Cromatografia Líquida de Alta Pressão , Herbicidas/análise , Têxteis , Triazinas , Água
12.
Molecules ; 26(21)2021 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-34770827

RESUMO

Walnut byproducts have been shown to exert functional properties, but the literature on their bioactive content is still scarce. Among walnut byproducts, walnut septum is a dry ligneous diaphragm tissue that divides the two halves of the kernel, exhibiting nutritional and medicinal properties. These functional properties are owing to its flavonoid content, and in order to explore the flavonoid fraction, an ultrasound-assisted (UAE) protocol was combined with solid phase extraction (SPE) and coupled to high-performance liquid chromatography with diode array detection (HPLC-DAD) for the determination of flavonoids in Greek walnut septa membranes belonging to Chandler, Vina, and Franquette varieties. The proposed UAE-SPE-HPLC-DAD method was validated and the relative standard deviations (RSD%) of the within-day and between-day assays were lower than 6.2 and 8.5, respectively, showing good precision, and high accuracy ranging from 90.8 (apigenin) to 97.5% (catechin) for within-day assay, and from 88.5 (myricetin) to 96.2% (catechin) for between-day assay. Overall, seven flavonoids were determined (catechin, rutin, myricetin, luteolin, quercetin, apigenin, and kaempferol) suggesting that the walnut septum is a rich source of bioactive constituents. The quantification results were further processed using ANOVA analysis to examine if there are statistically significant differences between the concentration of each flavonoid and the variety of the walnut septum.


Assuntos
Membrana Celular/química , Flavonoides/análise , Nozes/química , Extração em Fase Sólida , Ondas Ultrassônicas , Cromatografia Líquida de Alta Pressão
13.
Foods ; 10(9)2021 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-34574256

RESUMO

A high-pressure liquid chromatographic method coupled to diode array detector (HPLC-DAD) was developed for the determination of phenolic compounds that could be used as markers in authentication studies of walnuts belonging to the Chandler variety, originating from Bulgaria, Greece, and France. An ultrasound-assisted extraction (UAE) protocol applied in the extraction of phenolic compounds was optimized. The method was validated and the relative standard deviations (RSD%) of the within-day, and between-day assays was lower than 6.3 and 11.1, respectively, showing adequate precision, and good accuracy ranging from 86.4 (sinapic acid) to 98.4% (caffeic acid) for within-day assay, and from 90.1 (gallocatechin gallate) to 100.6% (gallic acid) for between-day assay. Eighteen phenolic compounds were determined belonging to the classes of phenolic acids and flavonoids. The quantification results were further processed with chemometrics, and a robust partial least square-discriminant analysis (PLS-DA) model was developed for the classification of the samples according to their geographical origin, proposing markers that could be used for the control of walnuts authenticity and the detection of fraudulent incidents.

14.
Molecules ; 26(18)2021 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-34576903

RESUMO

Reversed phase-high-pressure liquid chromatographic methodologies equipped with UV detector (RP-HPLC-UV) were developed for the determination of phenolic compounds and tocopherols in almonds. Nineteen samples of Texas almonds originating from USA and Greece were analyzed and 7 phenolic acids, 7 flavonoids, and tocopherols (-α, -ß + γ) were determined. The analytical methodologies were validated and presented excellent linearity (r2 > 0.99), high recoveries over the range between 83.1 (syringic acid) to 95.5% (ferulic acid) for within-day assay (n = 6), and between 90.2 (diosmin) to 103.4% (rosmarinic acid) for between-day assay (n = 3 × 3), for phenolic compounds, and between 95.1 and 100.4% for within-day assay (n = 6), and between 93.2-96.2% for between-day assay (n = 3 × 3) for tocopherols. The analytes were further quantified, and the results were analyzed by principal component analysis (PCA), and agglomerative hierarchical clustering (AHC) to investigate potential differences between the bioactive content of almonds and the geographical origin. A decision tree (DT) was developed for the prediction of the geographical origin of almonds proposing a characteristic marker with a concentration threshold, proving to be a promising and reliable tool for the guarantee of the authenticity of the almonds.


Assuntos
Cromatografia Líquida de Alta Pressão , Tocoferóis , Análise de Componente Principal , Prunus dulcis
15.
Talanta ; 234: 122710, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34364502

RESUMO

The determination of triazine herbicides in water samples is of utmost importance, due to their persistence and excessive use. However, since the concentration of triazine pesticides in real samples is low, an extraction/preconcentration step is typically required. Capsule phase microextraction (CPME) is a recently introduced sample preparation technique in which highly efficient sol-gel sorbents are encapsulated in a tubular polymer membrane. This particular design integrates the filtration and stirring mechanism into one extraction device, enabling the application of CPME for in situ sampling. In this study, CPME coupled to high performance liquid chromatography-diode array detection (HPLC-DAD) was employed for the first time for the determination of six triazine herbicides (i.e., simazine, cyanazine, atrazine, prometryn, terbuthylazine and propazine) in water samples. Microextraction capsules containing a moderately hydrophobic sol-gel Carbowax 20 M sorbent provided the highest extraction efficiency towards the examined pesticides. The main parameters affecting the adsorption and desorption steps of the CPME procedure were investigated and optimized. Under the selected conditions, limits of detection (signal/noise = 3.3) were 0.15 ng mL-1 for the target analytes. Moreover, the relative standard deviation for the within-day and between-days repeatability were less than 7.2% and 9.9%, respectively. The method was successfully applied to the analysis of mineral water, tap water, rainwater and lake water samples. The reported protocol could overcome the need for sample filtration prior to the sample preparation of the water samples, resulting in simplification of the overall sample handling, improved data quality with minimal loss of analytes and reduced sample preparation cost.


Assuntos
Herbicidas , Poluentes Químicos da Água , Cromatografia Líquida de Alta Pressão , Herbicidas/análise , Polietilenoglicóis , Triazinas/análise , Água , Poluentes Químicos da Água/análise
16.
J Pharm Biomed Anal ; 199: 114053, 2021 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-33819696

RESUMO

A fast fabric phase sorptive extraction method is presented herein for the rapid isolation of selected beta-blocker drugs from human serum and urine. Among many high efficiency sol-gel sorbent coated FPSE membranes, sol-gel CW20 M coated FPSE membrane was identified as the best FPSE membrane for the target beta-blocker drugs possessing logP values ranging from 0.1 (highly polar) to 3.1 (moderately polar). Due to the engineered affinity towards the analytes via complementary intermolecular interactions and high mass transfer rate of the analytes from the bulk sample solution to the FPSE membrane, the extraction is accomplished in relatively short time (15 min) while its high permeability permits the direct extraction of biological samples without any other pretreatment. The advantages of the fabricated extraction membrane were exploited for the determination of six beta-blockers (namely atenolol, nadolol, metoprolol, oxprenolol, labetalol and propranolol) in biological matrices in combination with UHPLC-ESI-MS/MS. Important parameters including extraction time, sample volume, sorbent size, elution solvent, etc. affecting the performance of the extraction were systematically investigated. The linearity of the method was evaluated in the range of 50-5000 ng mL-1 by constructing weighted (1/X) matrix-matched calibration curves. The intra-day and inter-day trueness were ranged between - 17.2 to 13.3% and - 10.8 to 12.6%, respectively. The intra-day and inter-day precision were less than 11.5 and 14.5 %, respectively. The proposed analytical scheme was successfully applied to the determination of the target drugs in human serum and urine.


Assuntos
Espectrometria de Massas em Tandem , Cromatografia Líquida de Alta Pressão , Humanos
17.
J Sep Sci ; 44(8): 1633-1640, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33448130

RESUMO

Monitoring the residual toxicant concentrations in foods is the key step for minimizing potential hazards. The huge interest about food contamination and exposure to endocrine disruptors such as bisphenol A has emerged the development of sensitive analytical methodologies to guarantee the safety and quality of foods. In this work, a green molecularly imprinted solid-phase extraction protocol coupled with high-performance liquid chromatography with UV detection was optimized following the principles of green analytical chemistry. An imprinted sol-gel silica-based hybrid inorganic-organic polymeric sorbent was used to monitor the leaching of bisphenol A from different packaging materials (glass vessels, cans, and polypropylene containers) in walnuts stored within a period of 6 months at 25 and 4°C. Extraction parameters including loading time (5-20 min), solvent type (acetonitrile, ethanol, methanol, acetone, acetonitrile:methanol, 50:50, v/v), and elution flow rate (0.2-1 mL/min) were optimized with one-factor-at-a-time method. The selected extraction optimum parameters incorporated elution with acetonitrile at 0.2 mL/min flow rate, for 10 min sample holding time. The imprinting factor was equal to 4.55 ± 0.26 (n = 3). The optimized method presented high recovery (94.3 ± 4.2%, n = 3), good linearity (>0.999), intra-assay repeatability (90.2-95.6%, n = 3), and interassay precision (86.7-93.1%, n = 3).


Assuntos
Compostos Benzidrílicos/análise , Contaminação de Alimentos/análise , Armazenamento de Alimentos , Impressão Molecular , Nozes/química , Fenóis/análise , Extração em Fase Sólida , Cromatografia Líquida de Alta Pressão , Espectrofotometria Ultravioleta
18.
Environ Sci Pollut Res Int ; 28(42): 59150-59164, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32577971

RESUMO

The guarantee of wine authenticity arises great concern because of its nutritional and economic importance. Phenolic fingerprints have been used as a source of chemical information for various authentication issues, including botanical and geographical origin, as well as vintage age. The local environment affects wine production and especially its phenolic metabolites. Integrated analytical methodologies combined with chemometrics can be applied in wine fingerprinting studies for the determination and establishment of phenolic markers that contain comprehensive and standardized information about the wine profile and how it can be affected by various environmental factors. This review summarizes all the recent trends in the generation of chemometric models that have been developed for treating chromatographic data and have been used for the investigation of critical wine authenticity issues, revealing phenolic markers responsible for the botanical, geographical, and vintage age classification of wines. Overall, the current review suggests that chromatographic methodologies are promising and powerful techniques that can be used for the accurate determination of phenolic compounds in difficult matrices like wine, highlighting the advantages of the applications of supervised chemometric tools over unsupervised for the construction of prediction models that have been successfully used for the classification based on their territorial and botanical origin.


Assuntos
Vinho , Cromatografia Líquida , Fenóis/análise , Vinho/análise , Fluxo de Trabalho
19.
Molecules ; 25(4)2020 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-32093410

RESUMO

The concept of metal-organic frameworks (MOFs) was first introduced in 1990; nowadays they are among the most promising novel materials. MOFs belong to a new class of crystalline materials that consist of coordination bonds between metal clusters (e.g., metal-carboxylate clusters and metal-azolate clusters), metal atoms, or rod-shaped clusters and multidentate organic linkers that contain oxygen or nitrogen donors (like carboxylates, azoles, nitriles, etc.); thus, a three-dimensional structure is formed [...].


Assuntos
Estruturas Metalorgânicas/química , Estruturas Metalorgânicas/síntese química
20.
Mini Rev Med Chem ; 20(1): 24-38, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31288718

RESUMO

Tricyclic Antidepressants (TCAs) are a group of the main category of antidepressant drugs, which are commonly prescribed to treat major depressive disorder. Determination of TCA drugs is very important for clinical and forensic toxicology, especially for therapeutic drug monitoring in various biofluids. High Performance Liquid Chromatography (HPLC) is a well-established technique for this purpose. A lot of progress has been made in this field since the past 10 years. Novel extraction techniques, and novel materials for sample preparation, novel columns and novel applications of analysis of various biofluids for the determination of TCAs in combination with other drugs are some typical examples. Moreover, advances have been performed in terms of Green Analytical Chemistry principles. Herein, we aim to discuss the developed HPLC methods that were reported in the literature for the time span of 2008-2018.


Assuntos
Antidepressivos Tricíclicos/análise , Antidepressivos Tricíclicos/farmacocinética , Cromatografia Líquida de Alta Pressão/métodos , Animais , Antidepressivos Tricíclicos/isolamento & purificação , Transtorno Depressivo Maior/tratamento farmacológico , Monitoramento de Medicamentos/métodos , Humanos , Extração Líquido-Líquido/métodos , Extração em Fase Sólida/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...